# USPE Vet Downdraft Necropsy Table: Configuration Sign-Off

Drawing / model: `USPE-VET-225`. Status: **UNSIGNED / NOT RELEASED FOR FABRICATION**.
This sheet records a proposed USPE configuration for review. It is not a completed engineering approval, an operating manual, a safety certification or an IP/legal clearance.

## Product and controlled artwork

- **Native product:** [USPE Vet Downdraft Necropsy Table](https://www.mymortuarycooler.com/products/uspe-vet-downdraft-table); record `gid://shopify/Product/15444324614446`.
- **Covered SKU(s):** `USPE-VET-225-01`.
- **Image:** `uspe-own-vet-225.jpg`; SHA-256 `699b7a7a9742ae4537e908e8758ae97fd1b5b412af32dc971eda6921bc76683f`.
- **Drawing:** `uspe-own-vet-225-signoff.jpg`; SHA-256 `edaf260cf5e470ea02130176fc7d544c5155853548158c234409acdfe6d9d057`.
- **Editable CAD:** `uspe-vet-225.step`; SHA-256 `33cb5c999d224a10d416d73827ed308629dca7f7b7177c5748931d4daf7accb9`.

The illustration is an original CAD configuration view, not a photograph of a manufactured product. Purchased instruments, controls, electrical devices and plumbing components are proposed external layouts; their actual manufacturer, model, rating, fit and supply must be specified before release.

## Configuration to confirm

- Quantity: ____________________
- Quote / PO reference: ____________________
- Selected model / exact SKU: ____________________
- Materials / finish: ____________________
- Accessories / upgrades: ____________________
- Facility / delivery location: ____________________

Existing native selectors, not new promised capabilities:

- **Configuration request:** Project configuration.

Hose color request: [ ] Blue  [ ] Red  [ ] Black  [ ] White  [ ] Stainless braided. Red may be illustrated; final supplied hose construction and suitability need confirmation.

## Proposed CAD envelope

| Drawing coordinate | Modeled overall span |
|---|---:|
| X across drawing | 1,524.0 mm |
| Y front-to-back | 823.9 mm |
| Z overall | 1,200.5 mm |

These values are measured from the proposed CAD, including modeled fixtures and overhangs. They are not verified production dimensions; do not substitute them for an approved shop drawing or assume the reference manufacturer’s ratings apply.

## Required reviews

- [ ] Confirm dimensions, working elevations, clearances and exact option interfaces.
- [ ] Fabricator confirms material grades, sections, gauges, welds, drain slopes and finish.
- [ ] Select actual purchased parts, approved BOM, supply and manufacturer documentation.
- [ ] Qualified reviewers address loads, stability, movement, restraints, electrical protection, plumbing/backflow and ventilation as applicable.
- [ ] Confirm image / CAD / quote revisions describe the same configuration.
- [ ] Obtain separate legal / patent / trade-dress and image-rights review where needed.

## Configuration acceptance

Name / organization: ____________________

Signature: ____________________    Date: ____________________

Accepted configuration and exceptions: ____________________

Configuration acceptance alone does not authorize fabrication or certify engineering, legal clearance, compatibility or regulatory compliance. Engineering approval: **not supplied**. IP/legal approval: **not supplied**.