The Dixell XR40CH Controller: Setting and Reading Your Mortuary Cooler Temperature
Every packaged PRO³ system on an AMC upright mortuary cooler ships with the Dixell XR40CH digital controller, preset to factory defaults. Here's the operator's short course.
Daily operations
- See the set-point: press and release SET — the display shows the target.
- Change the set-point: hold SET 2+ seconds until the °F LED blinks, adjust with UP/DOWN within 10 seconds, press SET again to store. Standard body holding is 34–40°F.
- Manual defrost: hold DEF 2+ seconds.
- Lock the keyboard: hold UP+DOWN 3 seconds ("PoF" displays); same combo unlocks ("Pon").
Reading alarms
Alarm codes flash alternating with temperature. "HA"/"LA" are max/min temperature alarms that self-clear when temperature normalizes; "P1–P4" are probe faults — check connections before replacing probes; "dA" means the door is open. Persistent alarms after temperature recovery warrant a service call from a licensed tech.
Don't tune blind
Defrost type, intervals, and termination temperatures are preset per application (medium-temp air defrost on standard coolers). Parameter changes in the hidden menu should follow the manual — wrong defrost settings show up as ice on the ceiling or a coil that never clears. The full controller section, parameter tables, and wiring diagrams are on our Packaged Refrigeration Manuals & Startup Guide.
Want 24/7 remote temperature records on top of the controller? That's what HALO monitoring adds — audit-ready compliance documentation with instant alerts.
Controller flashing a code you don't recognize?
Call us with the code on the display — we'll decode it and walk the fix with you or your tech.