L-Shaped Elevating Autopsy Table
USPE equipment
L-Shaped Elevating Autopsy Table
Model: USPE-AT-LE
Quote only
Request a quote for your selected model and configuration.
Production lead time is model- and configuration-specific. Confirm the current schedule in your written quote before ordering.
1-888-792-9315
140 Kwick Way Lane, Building 7, Johnson City, TN 37615
Product details
An L-shaped autopsy workstation with an elevating examination area and adjoining sink-side workspace. Plan orientation, working height, utilities and optional fittings together.
Quote only · Model USPE-AT-LE
Configuration overview
- L-shaped examination and sink-side work areas
- Elevating table format
- Perforated work-surface sections shown
- Integrated sink and adjacent work area shown
- Four real views cover the table, sink area and construction details
Specifications and approval requirements
| Model | USPE-AT-LE |
|---|---|
| Layout | L-shaped elevating autopsy workstation |
| Orientation | Confirm left- or right-wing layout by approved drawing |
| Work surface | Perforated sections shown; final arrangement confirmed by quote |
| Sink / fixtures | Shown configuration; fittings and inclusion confirmed by quote |
| Dimensions / travel / load rating | Project-specific confirmation required |
| Electrical / water / drain / exhaust | Coordinated facility review required |
Options to request
Selections are requests, not confirmed included equipment. Final specifications and compatibility require written approval.
- Left-wing orientation review
- Right-wing orientation review
- Height-range / control-location review
- Perforated grid configuration
- Sink size and position request
- Waste disposer requirement review
- Hydro-aspirator requirement review
- Hand-spray / washdown requirement
- Table-rinse requirement review
- Eyewash requirement review
- Evidence screen requirement
- Removable measuring-rule request
- Air / vacuum / gas service request
- Ventilation connection review
- Task-light / camera-support request
- Additional cabinetry request
Frequently asked questions
Can I select a left- or right-wing layout?
Add the required orientation to your quote. Confirm handedness against the room plan and approval drawing rather than relying on a photograph.
Are the planning dimensions confirmed specifications?
No. The sizing fields are project targets for review. Final USPE dimensions, elevation range, load rating and utility requirements must be confirmed in writing.
Are every pictured fitting and selected option included?
No. Photographs show a configuration, and option selections are requests. The accepted quote must list the base equipment, selected fittings and exclusions.
Does the table include a room exhaust system?
Do not assume so. Specify the intended procedure and have the facility team review equipment ventilation, ductwork and exhaust requirements.
Can this be quoted as a complete autopsy room?
Yes. Add carts, sinks, storage, grossing equipment and refrigeration to the equipment schedule, with the room plan and utility requirements.
Related equipment
Forensic pathology equipment · Vault morgue coolers · Laboratory casework
Custom configurations and coordinated RFQs
Custom configurations are available across our equipment and rack lines. Request custom overall dimensions, tray widths, tier count or spacing, bay count, roller arrangement, casters or leveling feet, work surfaces, drainage, utilities and room integration as applicable. Your written quote and approved drawings define the build, materials, load rating and confirmed compatibility; selecting an option is not engineering approval.
All custom equipment RFQs · Stainless rack configurations · 23-, 27- and 30-inch stainless tray RFQ · Storage and transfer package RFQ · Refrigeration project RFQ · Vault cooler project RFQ · Request a coordinated custom quote
Plan this equipment in the room
Medical examiner, coroner and hospital pathology projects often involve more than a table replacement. The examination position, sink-side working area, cart approach and storage route all affect the usable layout. An equipment RFQ should identify the individual models and the interfaces that need review, not describe an unverified collection of products as a complete engineered room.
Check before requesting the final configuration
- Examination workflow, number of stations and required operating positions.
- Left- or right-wing orientation, wall clearances and staff circulation.
- Model-specific electrical, water, drainage and ventilation connections.
- Cart approach, tray dimensions, transfer heights and rack access.
Compare similar and supporting equipment
- Autopsy Cart Chassis for 27-Inch Body Trays
- Autopsy Cart with Examination Top
- Autopsy Cart Chassis for a 32-Inch Tabletop
- Tilting Autopsy Cart
Read the Forensic pathology workstations with a coordinated handling route planning guide · Browse Forensic Pathology Solutions · Request a coordinated equipment quote
Compare this model in the autopsy workflow
Review both legs of the L-shaped footprint, sink-side working space and requested wing orientation. The room plan, written quote and approved drawing must establish the final dimensions, elevation range, supported load and included fittings.
Use the autopsy and mortuary table comparison to review actual models by layout and listed width. Coordinate supporting carts, storage racks and AMC vault cooler storage as separate equipment interfaces; being linked here does not establish compatible heights, fittings or supported loads.
For a multi-station project, continue with the forensic pathology equipment guide or emergency mortuary workflow. The accepted quote must identify the selected equipment, accessories, utility requirements and exclusions. Material names or drainage features alone are not infection-prevention or certification claims.
Your quote basket 0
Saved on this browser only. Adding models does not submit a request or place an order.
Review and request a quote