Equipment financing
Financing is subject to application and credit approval.
Apply with TimePayment (opens in a new tab)
ACHPopular categories
Trending now Most ordered by funeral homes this season
Checkout securely
Your payment information is encrypted
Product information
An embalming station organizes the specified water-control, work-surface or storage functions in a preparation room. Pricing for TITAN Flushing Embalming Station – Model 1036-9FS starts at $4,997.00 for the listed configuration.
For the TITAN 1036-9FS Flushing Embalming Station, use the model-specific user manual and separate water-control reference below. Confirm the selected configuration and utility connections before planning installation.
This equipment is quote-only. Request a written configuration and pricing review for your facility.
Form AME-OM-1036-9FS Rev. A · Last updated January 15, 2026 · PDF
TITAN 1036-9FS Flushing Embalming Station User Manual
Dimensioned drawings, specifications, utility requirements, state drain rules, installation, operation, cleaning, troubleshooting and warranty. Scan the QR code on the cover to return to this page.
Download User Manual All manuals & formsForm AME-OM-1036-9WCU Rev. B · Last updated October 29, 2026 · PDF, 16 pages
AME 1036-9WCU Water Control Unit Owner & Service Manual
Cutout and mounting, plumbing rough-in, commissioning, operation, numbered parts diagram with AME part numbers, plumber detail pages for the mixing valves, aspirator and vacuum breaker, care, troubleshooting, state drain codes and service records. Scan the QR code on the cover to return to this page.
Download Owner & Service Manual All manuals & formsForm AME-RI-1036-9FS Rev. A · Last updated October 26, 2026 · PDF
TITAN 1036-9FS Flushing Embalming Station Rough-In Sheet
One-page plumbing and electrical rough-in, in inches: 1½″ drain at 7″ above the floor, hot and cold supplies, junction box, mounting holes and Z-bar bracket, with a QR code back to this page.
Download Rough-In Sheet Forms libraryPairs with: TITAN 1036-ES Embalming Sink Station · Water Control Unit 1036-9WCU · All embalming stations · Manuals library
The TITAN 1036-9FS puts the flushing bowl, water, aspiration and rinse for the preparation table in one stainless fixture. A large wall-hung vitreous china bowl sits on the face of a heliarc-welded 304 stainless cabinet. The embalming table drain hose sets into the splash-cover port, and a push button flushes the bowl clean, so fluids are handled at the station instead of carried across the room. Built to order in the USA by American Mortuary Equipment.
Pair the station with an embalming table using the add-on picker above: the Economy Multi-Height Folding Embalming Table or the American Bariatric Hydraulic Embalming Table.
| Model | 1036-9FS |
|---|---|
| Cabinet | 32″ W × 20″ D × 40″ H to the top deck |
| Overall depth | 46″ including the flushing bowl |
| Overall height | 70½″ to the top of the faucet spout |
| Bowl rim height | 16½″ from the floor |
| Rear rough-in | 1½″ drain centered 16″ from the left, 7″ above the floor; hot ½″ at 12″ and cold ½″ at 20″ from the left, both 15″ above the floor; 4″ × 4″ junction box centered 27″ from the left, 21″ above the floor (rough-in sheet) |
| Construction | 304 stainless steel, heliarc welded, polished finish |
| Flushing fixture | Wall-hung vitreous china bowl with push-button flush valve |
| Faucet | Hot/cold mixing, tall gooseneck spout, wrist-blade handles |
| Aspirator | Hydro aspirator, vacuum breaker, reverse flow; cold water |
| Spray hose | Spray nozzle, 8 ft flexible hose |
| Electrical | 120 V, 60 Hz, 1 phase, 15 A; GFCI duplex receptacle with waterproof cover |
| Water supply | Hot and cold; 58–60 psi and 4 GPM at the hydro aspirator |
| Flush valve pressure | 10–100 psi; low-consumption valves need 25 psi running pressure |
| Mounting | Floor or wall mount |
Some states add preparation-room plumbing rules on top of the plumbing code. Confirm current rules with your state board and plumbing inspector before you order.
| State | Rule | Requirement |
|---|---|---|
| Pennsylvania | 49 Pa. Code §13.174 | Sink with running water and sewer connection with a 2-inch capacity drain pipe; aspirator of the non-backflow type or fitted with a non-backflow valve. |
| Maryland | COMAR 10.29.03.05 | Preparation room drain pipe at least 2 inches; floor drain in the preparation room. |
| Massachusetts | 239 CMR 3.07 · 248 CMR 10 | Flush-rim sink and floor drain; reduced-pressure (RPZ) or air-gap backflow protection on the water service. |
| Virginia | 18 VAC 65-20-580 | Preparation room equipped with a flush or slop sink. |
| Wisconsin | Wis. Admin. Code FD 1.09 | Flushing-rim or slop sink in the preparation room. |
| Louisiana | LSBEFD inspection standard | Permanently installed backflow preventer on the hydro-aspirator supply. |
Pennsylvania, Maryland and New Jersey require a 2″ drain in the funeral preparation room, and many cities and counties add their own plumbing rules on top of the state code. We build every plumbing item to the requirement that applies to your room, including 2″ drain outlets, backflow protection and other code items. Select the 2″ Drain Upgrade option on this page, and add anything else in your order notes.
How to get a code-compliant build
State rules change. Confirm the current requirement with your inspector before you order. Request a quote · Send a PO
Every station is built to order. Left- or right-hand layouts, custom widths, a commercial disposal, perimeter rinse or local ventilation can be added by quote; call 1-888-792-9315 or email [email protected] with your room layout. Installation by a licensed plumber and electrician is required and is not included. Shipping is calculated at checkout.
TITAN Hydraulic Table & Flushing Embalming Station Package. Review the package page for exactly what is included, the selected configuration and current price. This individual item remains available separately.
This station ships with the AME Water Control Unit plate (model 1036-9WCU). Its fill faucet, mixing valves, spray rinse gooseneck, vacuum breaker, hydro-aspirator, cold-water valve, sight drain, hoses and hardware are all available as AME replacement parts. Match the installed part to the numbered diagram, then open the part page for the detail photo and plumber notes.
| Item | AME part no. | Description |
|---|---|---|
| 1 | AME-WCU-FILL | Tall fill faucet with 18 in. swing nozzle |
| 2, 3 | AME-WCU-MIX | Single-lever mixing valve (2 per unit); cartridge, handle, hoses |
| 4 | AME-WCU-RINSE | Spray rinse gooseneck with vacuum breaker, tip and 10 ft hose |
| 5 | AME-WCU-VB | Atmospheric vacuum breaker, 1/2 in. NPT; repair kit |
| 6 | AME-WCU-ASP | Reverse-flow hydro-aspirator; venturi, handle, service kit, wand head, extension |
| 7 | AME-WCU-CWV | Cold-water control valve, cross handle |
| 8 | AME-WCU-DRAIN | Sight drain assembly with 1-1/2 in. tailpiece |
| 9 | AME-WCU-HOSE-ASP10 | Clear aspirator hose, 10 ft; 5 ft sight-drain hose |
| 10 | AME-WCU-HDW | Mounting hardware kit, 4 × 10-24 × 2 in. |
| 11 | AME-WCU-MIX-HOSE | Braided supply hoses, 16 in., pair |
All AME replacement parts are quote only: open the part page and use Add to Quote, or call 1-888-792-9315 with the model, serial number and part number. Parts carry a one-year warranty with proper use (replacement parts only, no labor); parts sales are final.
Shop the complete Water Control Unit parts family · Owner and service manual with removal and refit steps (PDF)
Embalming station planning guide. For operating and service instructions, use this product's model-specific manual rather than the general planning guide.
Review the listed specifications, selected options and included items before ordering. Use the configuration selector for the current price and availability; do not assume that accessories pictured with a product are included unless the listing says so.
Source funeral supplies and mortuary equipment from one supplier, with nationwide shipping. For an equipment package or a multi-location order, request an itemized quote with the selected products, quantities and delivery ZIP codes. Confirm freight and delivery requirements for the equipment you choose.
Review the payment methods offered at checkout for your order. If a payment plan is available, its options and eligibility are shown by the provider. The equipment price and any financing cost are separate; compare the full payment terms before choosing a plan.
Enter payment details only in checkout or the payment provider's application. Use general customer support for product and order questions, not for sending full card numbers or sensitive financing information.
Review Product details for the published product information, and confirm the specifications of your selected configuration before ordering.
| Eyewash & Drench options | No Eyewash, Eyewash – Left Side, Eyewash – Right Side, Eyewash + Drench Hose – Left Side, Eyewash + Drench Hose – Right Side |
|---|---|
| Drain Outlet options | Standard Drain, 2″ Drain Upgrade |
| Brand / vendor | TITAN Pet |
|---|---|
| Equipment type | Pet Mortuary Flushing Station |
| Model | 1036-9FS |
Published dimensions remain in Product details when a separate dimensions section is not available.
Contact our team with the product name and the specification or option you want to confirm.
Include the product, quantity, required configuration and delivery location in your quote request.
Open Shipping & support for the published freight, returns and custom-order policy links.
Product-specific documents and planning links remain in Product details when a separate resources section is not available.
Review the published policies and confirm product-specific requirements before placing your order.
Purchase through the product options above, or use one of these support paths for a financed or institutionally quoted order.
Financing is subject to application and credit approval.
Apply with TimePayment (opens in a new tab)Request documented pricing, freight planning, and configuration support before issuing a purchase order.
Request a formal quoteEstimates are for qualified buyers with approved credit (WAC) and reflect the equipment price only. Shipping, freight, and applicable taxes are not included and will increase your total and payments. Final amounts are set at checkout or on your quote.
Government and institutional buyers: request a PO quote.
Values below are references recorded for this listing, not a new classification determination. Missing or unverified information must be confirmed for the exact configuration and purchasing system.
Reference classifications for RFQ, bid, grant and purchase-order preparation. Codes, model numbers and any GSA Schedule SIN are different identifiers, not certifications; this panel does not assign a SIN or imply a contract award, set-aside status, government approval or universal regulatory compliance.
Request a quote or submit a PO · Government buyer desk · Financing & leasing